MIL-R-10509J
TABLE V. Qualification inspection.
Inspection |
Requirements paragraph |
Method paragraph |
Number of samples |
Number of defects allowed 1/ |
Group I Visual and mechanical inspection 2/ DC resistance Seal (as applicable) |
3.1, 3.3 to 3.4.1 incl. and 3.24 to 3.26 incl. 3.7 3.8 |
4.7.1 4.7.2 4.7.3 |
100 percent |
0 |
Group II Thermal shock Low temperature operation Short time overload Terminal strength Seal (as applicable) |
3.9 3.10 3.11 3.12 3.8 |
4.7.4 4.7.5 4.7.6 4.7.7 4.7.3 |
10 |
1 |
Group III Dielectric withstanding voltage Insulation resistance Thermal shock Resistance to soldering heat Moisture resistance |
3.13 3.14 3.9 3.15 3.16 |
4.7.8 4.7.9 4.7.4 4.7.10 4.7.11 |
10 |
|
Group IV Resistance temperature characteristic Life Seal (as applicable) |
3.17 3.18 3.8 |
4.7.12 4.7.13 4.7.3 |
10 |
|
Group V Solderability Shock (specified pulse) Vibration, high frequency Resistance to solvents Seal (as applicable) |
3.19 3.20 3.21 3.22 3.8 |
4.7.14 4.7.15 4.7.16 4.7.17 4.7.3 |
10 |
1/ Failure of a resistor in one or more tests of a group shall be charged as a single defective.
2/ Marking shall be considered defective only if the marking is illegible.
4.6 Conformance inspection.
4.6.1 Inspection of product for delivery. Inspection of product for delivery shall consist of group A and group B inspections.
4.6.2 Inspection lot. An inspection lot, as far as practical, shall consist of all the resistors of the same style, characteristic, and protective enclosure or coating.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.