MIL-PRF-49462C
TABLE V. Qualification inspection.
Inspection
Requirement
Method
Number of
Number of
paragraph
paragraph
sample units
defects allowed
Group I
Visual and mechanical
DC resistance
All samples
Power conditioning
Group IA
Solderability
12 sample units
1
any value
Resistance to solvents
Group II
Thermal shock
5 high
Low temperature operation
5 critical
Terminal strength
5 low
Group III
Dielectric withstanding voltage
Insulation resistance
5 high
5 critical
Thermal shock
5 low
Moisture resistance
Group IV
Life
5 high
1
5 critical
Resistance temperature
5 low
characteristic
Group V
5 high
Shock (specified pulse)
5 critical
Vibration, high frequency
5 low
Group VI
Outgassing (when applicable)
10 sample units
0
any value
4.4.2 Test routine. Sample units will be subjected to the qualification inspection specified in table V in
the order shown. All sample will be subjected to the inspection of group I. The 60 sample units of 5
percent resistance tolerance will then be divided as specified in table V for groups II to V, inclusive and
subjected to the inspection for their particular group. When applicable 10 additional sample units will be
submitted to the inspection of group VI. When approval for a lower resistance tolerance is desired, 20
additional sample units will be submitted to the inspection of group I.
4.4.3 Failures. Failures in excess of those allowed in table V shall be cause for refusal to grant
qualification.