MIL-PRF-39015E
3.8 Conditioning. When resistors are tested as specified in 4.8.2, there shall be no evidence of
mechanical damage and the change in resistance shall not exceed ±0.5 percent for resistance values of
100 ohms or greater, and ±(0.5 percent +0.05 ohm) for values below 100 ohms.
3.9 Peak noise. When resistors are tested as specified in 4.8.3, the peak noise resistance shall not
exceed 500 ohms, with the following exceptions:
In group I of table V:
Shall not exceed 100 ohms.
In group IV of table V:
Shall not exceed 200 ohms.
In table VI
Shall not exceed 100 ohms.
3.10 DC resistance.
3.10.1 Total resistance. When measured as specified in 4.8.4.1, the total direct current (dc) resistance
shall not deviate from the specified nominal (see 3.1) by more than ±5 percent.
3.10.2 Absolute minimum resistance. When measured as specified in 4.8.4.2, the absolute minimum
resistance shall not exceed 0.25 percent of the nominal total resistance value, or 1 ohm, whichever is
greater.
3.10.3 End resistance. When measured as specified in 4.8.4.3, the end resistance shall not exceed 2
percent of the nominal total resistance value, or 1 ohm, whichever is greater.
3.10.4 Resistance value deviations. All maximum deviations as specified in this section are to be
*
considered absolute limits with the exception of the contact resistance adjustments.
3.11 Immersion (not applicable to L terminals). When resistors are tested as specified in 4.8.5, no
continuous stream of bubbles shall emanate from any concentrated point of the resistor. When resistors
are subjected to the dye penetrate test, there shall be no evidence of dye in the internal cavities.
3.12 Continuity. When resistors are tested as specified in 4.8.6, the change in voltage or resistance
shall be smooth and unidirectional throughout the effective electrical travel.
3.13 Actual effective electrical travel. When resistors are tested as specified in 4.8.7, the number of
turns of the operating shaft necessary for the contact arm to traverse the resistance element shall be as
specified (see 3.1).
3.14 Dielectric withstanding voltage. When resistors are tested as specified in 4.8.8, there shall be no
evidence of damage, arcing, or breakdown. The leakage current shall not exceed 1 milliampere.
3.15 Insulation resistance. When resistors are tested as specified in 4.8.9, the dry insulation
resistance shall not be less than 1,000 megohms.
3.16 Torque.
3.16.1 Operating. When resistors are tested as specified 4.8.10.1, the torque required to move the
contact arm shall be as specified (see 3.1).