1. SCOPE
1.1 Scope. This specification covers the general requirements for nonestablished reliability (non-ER)
and established reliability (ER), lead screw actuated; wire wound variable resistors with a contact bearing
uniformly over the surface of the entire resistive element, wound linearly, when positioned by a multiturn
lead screw actuator. These resistors are capable of full load operation (when the maximum resistance is
engaged), at a maximum temperature of 85șC and are capable for continuous operation, when properly
derated, at maximum temperature of 150șC (see 3.6), with a resistance tolerance of ±5 percent. The ER
resistors have life failure rate (FR) levels ranging from 1.0 percent to 0.001 percent per 1,000 hours (see
1.2.1.4). These FR levels are established at a 60 percent confidence level on the basis of life tests.
1.2 Classification.
*
1.2.1 Part or Identifying Number (PIN). Resistors specified herein are identified by the PIN which
consists of the basic number, associated specification, and a coded number.
M39015/2
-
001
P
M
│
│
│
│
│
│
│
│
Product level
Associated
Resistance
Terminals
specification
value designator
(see 1.2.1.3
designator
number
(see 1.2.1.2)
& 6.14)
(see 1.2.1.4)
1.2.1.1 Style. The style is identified by the three-letter symbol "RTR" followed by a two-digit number;
the letters identify lead screw actuated, wire wound, variable resistors, and the number identifies the
physical size.
Comments, suggestions, or questions on this document should be addressed to: US Army
Communications-Electronics Command and Fort Monmouth, ATTN: AMSEL-LC-LEO-E-EP, Fort
Monmouth, NJ 07703-5023 or emailed to Jeffery.Carver@mail1.monmouth.army.mil. Since contact
information can change, you may want to verify the currency of this address information using the
ASSIST Online database at https://assist.daps.dla.mil.
AMSC N/A
FSC 5905
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business