MIL-PRF-39015E
TABLE V. Qualification inspection.
Inspection
Requirement
Method
Number of
Number of
defectives
paragraph
paragraph
sample units
1/
allowed 2/
Group I 3/ 4/
Conditioning
All sample
Peak noise
Units
Not applicable
Total resistance
Immersion
(not applicable to L terminals)
Group IA 4/
Visual and mechanical inspection 5/
(Visual and
incl., and 3.33 and 3.34 incl.
mechanical
Continuity
All sample
inspection not
Actual effective electrical travel
unit except
applicable)
Absolute minimum resistance
those for
End resistance
group II
Dielectric withstanding voltage
0
Insulation resistance
Torque
Thermal shock
Group II
6 any value
0
Solderability
(applicable to terminals P, W, X, and Y)
Group III
Resistance temperature characteristic
12
6 high
Moisture resistance
6 low
Peak noise
Group IV
Shock (specified pulse)
Vibration, high frequency
12
6 high
Peak noise
6 low
1
Salt spray (corrosion)
Group V
Resistance to soldering heat
(applicable to terminals P, W, X, and Y)
Low temperature operation
Low temperature storage
12
6 high
High temperature exposure
6 low
Peak noise
Integrity of shaft
Group VI
Rotational life
1
12
6 high
Peak noise
6 low
Terminal strength
Group VII
Life
102 51 high
1
51 low
Group VIII
Resistance to solvents
3 any value
0
Group IX
Fungus 6/
10
0
See footnotes on next page.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business