MIL-PRF-39015E
4.8.8 Dielectric withstanding voltage (see 3.14).
4.8.8.1 Atmospheric pressure. Resistors shall be tested in accordance with method 301 of
MIL-STD-202. The following details shall apply:
a. Special preparations: Resistors shall be mounted on metal plates of sufficient size to extend
beyond the resistor extremities, and in such a manner that measurements can be made between
the terminals tied together and any other external metal parts.
b. Magnitude of test voltage: 900 volts rms.
c.
Nature of potential: From an alternating current (ac) supply at commercial line frequency and
waveform.
d. Points of application of test voltage: Between the resistor terminals connected together and the
metal portions of the resistors and metal mounting plate.
e. Examinations and measurements: During the tests, the leakage current shall be monitored and
the resistors examined for evidence of arcing and breakdown. At the conclusion of the test,
resistors shall be examined for evidence of damage.
4.8.8.2 Barometric pressure. Resistors shall be tested in accordance with method 105 of
MIL-STD-202. The following details and exceptions shall apply:
a. Method of mounting: As specified in 4.8.8.1a.
b. Test condition: C.
c.
Period of time at reduced pressure prior to applicable of potential: One minute.
d. Test during subjection to reduced pressure: A potential of 350 volts rms from an ac supply at
commercial line frequency and waveform shall be applied for 1 minute.
e. Points of application: As specified in 4.8.8.1d.
Examinations and measurements: As specified in 4.8.8.1e.
f.
MIL-STD-202. The following details shall apply:
a. Special preparation: As specified in 4.8.8.1a.
b. Test condition: A or B, whichever is more practicable.
c.
Points of measurement: As specified in 4.8.8.1d.
24