MIL-PRF-39005G
TABLE IX. Qualification inspection.
Inspection
Requirement
Test
Number of
Number of
paragraph
method
sample units
failures
permitted
paragraph
for inspection
1/
Certification requirements: 2/
Weldable terminals
N/A
Flux
Group I
Conditioning 3/ 4/
DC resistance
Group IA
All sample units
0
Visual and mechanical examination 3/ 5/
(except groups
3.5.6 inclusive,
IB and VII)
3.29 inclusive
Short time overload 3/
Thermal shock 3/
Group IB
10 sample units
Solderability
both leads;
("L" terminal only)
20 sample units
1
single leads
Group II
Dielectric withstanding voltage 6/
30 sample units
Terminal strength
high value
1
Group III
Insulation resistance
Moisture resistance
30 sample units
1
1
Dielectric withstanding voltage 6/
high value
Terminal strength
Group IV
Resistance to soldering heat
30 samples units
Shock, specified pulse
high value
1
Vibration, high frequency
Group V
10 high value
Resistance temperature characteristic 3/
10 - 10,000 ohms
Low temperature storage
1
30
or nearest
Low temperature operation
10 low value
34 high value
Group VI
102 34 - 10,000 ohms
Life
1
34 low value
Group VII
Fungus 7/
10
19 any value
0
Resistance to solvents
9
34 high value
Group VIII
102 34 - 10,000 ohms
High temperature exposure
1
34 low values
See footnotes at top of next page.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business