MIL-PRF-39005G
4.8.16 Low temperature operation (see 3.20). Following the final dc resistance measurement specified
in 4.8.5, the resistors, mounted as specified in 4.8.15.1, shall again be placed in a cold chamber at room
temperature. The temperature shall be gradually decreased to -55°C +0°C, -0°C within a period of not
less than 1 hour 30 minutes. For conformance inspection only, and at the option of the manufacturer, the
resistors may be placed when the chamber is already at the extreme low temperature. After 1 hour of
stabilization at this temperature, full rated continuous working voltage as specified in 3.5.8 shall be
applied for 45 minutes. The resistors may be loaded individually or in parallel. Fifteen minutes +5
minutes, -0 minutes after removal of voltage, the temperature in the chamber shall be gradually increased
to room temperature with a period of not more than 8 hours. The resistors shall then be removed from
the chamber and maintained at a temperature of 25°C ±5°C for a period of approximately 24 hours. The
dc resistance shall then again be measured as specified in 4.8.5. Resistors shall then be examined for
evidence of mechanical damage.
following details and exceptions shall apply.
a. Mounting: Resistors shall be mounted on lightweight terminals. The effective length of each
terminal shall be .375 inch ±.0625 inch (9.53 mm ±1.588 mm). The method of attaching the
resistor leads to the terminals shall be at the option of the manufacturer. Resistors shall be so
arranged that the temperature of any one resistor shall not appreciably influence the temperature
of any other resistor. Regardless of the mounting and termination method selected, the integrity of
the connections to each resistor undergoing test shall be verified periodically to assure that each
part is tested with the voltage specified in 4.8.17d.
b. Test temperature: Qualification inspection and extended life testing: Ambient temperature
125°C +15°C, -0°C.
c. Initial measurements: Measurements may be made inside or outside the chamber.
(1) Inside the chamber - When measurements are to be made inside the chamber, the initial dc
resistance shall be measured after mounting at the applicable test temperature, after
temperature stabilization, and within 8 hours of exposure of the resistors to the test
temperature. This initial measurement shall be used as the reference temperature for all
subsequent measurements under the same conditions.
(2) Outside the chamber: When measurements are to be made outside the chamber, the initial dc
resistance shall be measured after mounting at the room temperature. This initial
measurement shall be used as the reference temperature for all subsequent measurements
under the same conditions.
d. Operating conditions: Rated dc continuous working voltage, or filtered or nonfiltered full wave
rectified ac voltage shall be applied intermittently, 1 hour 30 minutes "on" and 30 minutes "off", for
the applicable number of hours (see 4.8.17f), and at the applicable test temperature. "On time"
shall be 75 percent of the total elapsed time. During the "on" cycle, the voltage shall be regulated
and controlled to maintain ±5 percent of the rated continuous working voltage.
e. Test condition: Two thousand hours for qualification inspection continued to 10,000 hours. Ten
thousand hours for FRL determination of group C.