MIL-PRF-39005G
4.8.7.2 Barometric pressure (reduced). Resistors shall be tested in accordance with method 105 of
MIL-STD-202. The following details and exceptions shall apply.
a. Method of mounting: As specified in 4.8.7.1a.
b. Initial measurement: DC resistance shall be measured as specified in 4.8.5.
c. Test condition: D.
d. Test voltages during subjection to reduced pressure: 200 volts.
e. Nature of potential: As specified in 4.8.7.1d.
f. Duration of application of test voltage: 5 seconds.
g. Rate of application of test voltage: 100 volts per second.
h. Points of application of test voltage: As specified in 4.8.7.1g.
i. Measurement after test: DC resistance shall be measured as specified in 4.8.5.
j. Examinations after test: As specified in 4.8.7.1i.
4.8.8 Terminal strength (see 3.12). Resistors shall be tested in accordance with method 211 of
MIL-STD-202. The following details and exceptions shall apply.
a. Test conditions: A and D (pull test and twist test, respectively). Applied force (A): 4.5 pounds.
Resistor clamped by 1 lead and force applied to other lead.
b. Measurement before and after test: DC resistance shall be measured as specified in 4.8.5.
4.8.9 Insulation resistance (see 3.13). Resistors shall be tested in accordance with method 302 of
MIL-STD-202 with the following exceptions:
a. Test condition: A or B, whichever is greater.
b. Special preparation: As specified in 4.8.7.1a.
c. Points of measurement: As specified in 4.8.7.1g.