MIL-PRF-39005G
f. Measurements during test:
(1) Qualification inspection: DC resistance shall be measured at the end of the 30 minutes "off"
periods after 250 hours +72 hours, -24 hours; 500 hours +72 hours, -24 hours; 1,000 hours
+72 hours, -24 hours; and 2,000 hours +96 hours, -24 hours have elapsed.
(2) Extended life testing: DC resistance shall be measured at the end of the 30 minute "off"
periods after 250 hours +72 hours, -24 hours; 500 hours +72 hours, -24 hours; 1,000 hours
+72 hours, -24 hours; 2,000 hours +96 hours, -24 hours; 4,000 hours +96 hours, -24 hours;
6,000 hours +96 hours, -24 hours; 8,000 hours +96 hours, -24 hours; and 10,000 hours +120
hours, -0 hour have elapsed. Measurements shall be made as near as possible to the
specified time but may be adjusted so that measurements need not be made during other than
normal work days.
(3) Measurement outside chamber: When measurements are made outside the chamber,
resistors shall be outside the chamber for a minimum of 45 minutes and stabilized before
measurements.
g. Examination after test: Resistors shall be examined for evidence of mechanical damage.
Resistors shall be examined for evidence of fungus.
4.8.19 Resistance to solvents (see 3.23). Resistors shall be tested in accordance with method 215 of
MIL-STD-202. The following details shall apply:
a. The marked portion of the resistor body shall be brushed.
c. Resistors shall be examined for mechanical damage and legibility of markings.
4.8.20 High temperature exposure (see 3.24).
a. Mounting: Resistors shall be mounted by their normal mounting means.
b. Initial measurements: DC resistance shall be measured as specified in 4.8.5 at room ambient
conditions.
c. Procedure: Following initial resistance measurements resistors shall be placed in a chamber
maintained at 145°C ±5°C for a period of 2,000 hours with no load applied.
d. Measurements during test: At 250 hours +48 hours, -0 hours, resistors shall be removed from the
chamber and permitted to stabilized at room temperature and within 6 hours after removal, the dc
resistance shall be measured as specified in 4.8.5. Resistors shall be examined for evidence of
mechanical damage.
e. Final measurements: After removal from test chamber, resistors shall be permitted to stabilize at
room ambient temperature, and within 6 hours after removal, cleaning of the leads will be allowed.
The dc resistance shall be measured as specified in 4.8.5. Resistors shall be examined for
evidence of mechanical damage.