MIL-PRF-39017G
4.8.19 High temperature exposure (see 3.25).
a. Mounting: Resistors shall be mounted by means other than soldering or may be placed in trays.
When trays are used, they must be designed to present a minimum construction to the airstream;
so that the specified ambient temperature can be achieved throughout the chamber.
b. Initial measurements: DC resistors shall be measured as specified in 4.8.3 at room ambient
conditions.
c.
Procedure: Following initial resistance measurements resistors shall placed in a chamber
maintained at 150°C, +15°C, -0°C for 100 PPM (125°C +15°C, -0°C for resistance temperature
coefficient of 350 PPM) (see 3.1) for a period of 2,000 hours +72 hours, -0 hours with no load.
d. Measurements during test: At 250 hours +48 hours, -0 hours, resistor shall be removed from
chamber and permitted to stabilize at room temperature and within 6 hours after removal, the dc
resistance shall be measured as specified in 4.8.3. Resistors shall be examined for evidence of
mechanical damage.
e. Final measurements: After removal from the test chamber resistors shall be permitted to stabilize
at room ambient temperatures and within 6 hours after removal, the dc resistance shall be
measured as specified in 4.8.3. Resistors shall be examined for evidence of mechanical
damage.
4.8.21 Aqueous-extract-conductivity test procedure (see 3.5.1).
4.8.21.1 Outline of method. The sample is extracted with hot water. The conductivity of electrolytic
surface contaminants is measures with a conductivity bridge or resistance indicator and compared with
deionized or distilled water blank.
4.8.21.2 Apparatus.
4.8.21.2.1 Conductivity bridge. A conductivity bridge or resistance indicator shall be used with the
capability of measuring resistance up to at least 2 megohms. Within the range of 0.3 megohms to 1
megohm inclusive, the accuracy of adjustment shall be within 5 percent.
4.8.21.2.2 Constant temperature bath. A water bath maintained at 25°C ±0.5°C. If the conductivity
bridge as described in 4.8.21.2.1 is cable of automatic temperature compensation to within ±0.5°C, the
water bath temperature shall be 25°C ±0.5°C.
4.8.21.2.3. Beakers. Two acid and alkali-resistant glass, 125 milliliter (ml), tall form beakers or any
beakers of such dimension that the dip-type cell is immersed in 100 ml of liquid contained therein, the
electrodes are fully covered.