4.8 Methods of inspection.
4.8.1 Network handling procedures.
4.8.1.1 Method A. When specified herein, the networks shall be unmounted or tested using pressure type
contacts. The test fixture shall be such that it shall not be the cause of, nor contribute to, any failure of the network in
any test for which it may be used.
4.8.1.2 Method B. When specified herein, the networks shall be mounted on test boards of fiberglass base,
nominally .0625 inch (1.589 mm) thick. Mounting accomplished with either Sn60A or Sn63A solder shall be in
accordance with J-STD-006. After mounting, the boards must be thoroughly cleaned to remove all traces of flux
residue by an appropriate cleaning method, then oven dried for 5 minutes minimum at 125OC ±10OC. The test board
and mounting procedure shall be such that it shall not be the cause of, nor contribute to, any failure of a network in
any test for which it may be used. If more than one network is placed on a given test board, the networks shall be
spaced a minimum of 1.00 inch (25.4 mm) from each other.
4.8.2 Visual and mechanical inspection. Networks shall be inspected to verify that the materials, design,
construction, physical dimensions, and workmanship are in accordance with the applicable requirements
4.8.3 Thermal shock (see 3.8). Networks shall be tested in accordance with method 107 of MIL-STD-202. The
following details and exception shall apply:
a.
Mounting: As specified in 4.8.1, method A.
Measurement before cycling: DC resistance shall be measured as specified in 4.8.5.
b.
c.
Test condition: For group A inspection and qualification group I, test condition B. For qualification group V
and group C inspection, test condition B-1.
d.
Measurement after cycling: Within 3 hours after stabilization at room temperature, dc resistance shall be
measured as specified in 4.8.5. For group A inspection and qualification group I, dc resistance shall be
measured following the test of 4.8.4.
e.
Following the test, the networks shall be inspected for evidence of mechanical damage.
4.8.4 Power conditioning (see 3.9). Networks shall be tested in accordance with method 108 of MIL-STD-202.
The following details and exceptions shall apply:
a.
Mounting: As specified in 4.8.1, method A.
O
O
O
Test temperature and tolerance: 25 C, +20 C, -5 C.
b.
c.
Initial measurements: Measurements may be made inside or outside the chamber.
(1) Inside chamber: When measurements are to be made inside the chamber, the initial dc resistance shall
be measured, at the applicable test temperature, after temperature stabilization, and within 8 hours of
exposure of the networks to the test temperature. This initial measurement shall be used as the
reference temperature for all subsequent measurements under the same conditions.
(2) Outside chamber: When measurements are to be made outside the chamber, the initial dc resistance
shall be measured at room temperature. This initial measurement shall be used as the reference
temperature for all subsequent measurements under the same condition.