MIL-R-93F
APPENDIX A
A.5. SOLDER DIP (RETINNING) LEADS
A.5.1 Solder dip (retinning) leads. The manufacturer may solder dip/retin the leads of product supplied to this specification provided the solder dip process has been approved by the qualifying activity.
A.5.2 Qualifying activity approval. Approval of the solder dip process will be based on one of the following options:
a. When the original lead finish qualified was hot solder dip lead finish 52 of MIL-STD-1276. (NOTE: The 200 microinch maximum thickness is not applicable). The manufacturer shall use the same solder dip process for retinning as is used in the original manufacture of the product.
b. When the lead originally qualified was not hot solder dip finish 52 of MIL-STD-1276 as prescribed in A.5.2a, approval for the process to be used for solder dip shall be based on the following test procedure:
(1) Thirty samples of any resistance value for each style and lead finish are subjected to the manufacturer's solder dip process. Following the solder dip process, the resistors are subjected to the dc resistance test (and other group A electricals). No defects allowed.
(2) Ten of the 30 samples are then subjected to the solderability test. No defects allowed.
(3) The remaining 20 samples are subjected to the resistance to soldering heat test followed by the moisture resistance test. No defects allowed.
A.5.3 Solder dip/retinning options. The manufacturer may solder dip/retin as follows:
a. After the 100 percent group A screening tests: Following the solder dip/retinning process, the electrical measurements required in group A, subgroup 1, 100 percent screening tests shall be repeated on 100 percent of the lot (NOTE: The manufacturer may solder dip/retin prior to the 100 percent electrical measurements of the group A, subgroup 1 tests). The percentage defective allowable (PDA) for the electrical measurements, shall be the subgroup 1 tests.
b. As a corrective action, if the lot fails the group A solderability test: The lot may be retinned no more than two times. The lot after retinning shall be 100 percent screened for group A electrical requirements (dc resistance). Any parts failing (lot not exceeding PDA for group A, subgroup 1, see 4.6.2.1.1) these screens shall not be supplied to this specification. If electrical failures exceeding 1 percent of the lot are detected after the second retinning operation, the lot shall not be supplied to this specification.
c. After the group A inspection has been completed: Following the solder dip/retinning process, the electrical measurements required in group A, subgroup 1, 100 percent screening test shall be repeated on 100 percent of the lot. The PDA for the electrical measurements shall be as for the subgroup 1 tests. Following these tests, the manufacturer shall submit the lot to the group A solderability test as specified in 4.6.2.2.
28