MIL-R-93F
* 4.7.9.2 Barometric pressure (reduced). Resistors shall be tested in accordance with method 105 of
MIL-STD-202. The following details and exceptions shall apply:
a. Method of mounting: As specified in 4.7.9.1a.
b. Initial measurement: DC resistance shall be measured as specified in 4.7.2. c. Test condition: D.
d. Test voltage during subjection to reduced pressure: 200 volts. e. Nature of potential: As specified in 4.7.9.1d.
f. Duration of application of test voltage: 5 seconds.
g. Rate of application of test voltage: 100 volts per second.
h. Points of application of test voltage: As specified in 4.7.9.1g.
i. Measurement after test: DC resistance shall be measured as specified in 4.7.2. j. Examination after test: As specified in 4.7.9.1i.
4.7.10 Terminal strength (see 3.14). Resistors shall be tested in accordance with method 211 of
MIL-STD-202. The following details and exceptions shall apply:
a. Test condition: A and D (pull test and twist test, respectively). Applied force (A): 4.5 pounds.
Resistor clamped by 1 lead and force applied to other lead.
b. Measurement before and after test: DC resistance shall be measured as specified in 4.7.2.
18