MIL-PRF-914/1A
3. REQUIREMENTS
3.1 General. The requirements for acquiring the product described herein shall consist of this document
and MIL-PRF-914.
3.2 Interface and physical dimension. The resistor networks shall meet the interface and physical
dimensions specified on figure 2.
3.3 Power rating. The power ratings for schematic A, schematic B, and schematic J shall be as specified
in table I.
TABLE I. Power ratings.
Schematics
Characteristics
Characteristics
K and M
C, R, H, and V
Element
Network
Element
Network
(watts)
(watts)
(watts)
(watts)
0.42
0.060
1.0
0.16
A
0.42
0.032
1.0
0.08
B
1.0
0.08
J
3.4 Power conditioning. The power applied for power conditioning for schematic A, schematic B, and
schematic J shall be one and one-half times rated power.
3.5 Temperature range. The operating temperature range shall be from -55 C to +125 C.
3.6 Voltage rating. The maximum voltage rating shall be 50 V dc.
3.7 Resistance range. The resistance range shall be 10 ohms to 2.2 megohms.
3.8 Standard resistance values. The standard resistance values and the resistance designator for the "J"
schematic are as specified in table II.
3.9 Resistance tolerance. Resistors are available in (B) ±0.1 percent, (D) ±0.5 percent, (F) ±1 percent,
(G) ±2 percent, and (J) ±5 percent tolerances.
3.10 Termination. Resistors are available in termination C, termination F, and termination J.
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection shall be in accordance with MIL-PRF-914.
4.2 "J" schematic tests. For the tests on "J" schematic, the dc resistance measurements, resistance
temperature characteristic measurement, and short time overload application shall be made between each
terminal and applicable common terminal without compensation for the shunt circuits to determine the
acceptability to section 3 requirements.