MIL-PRF-83530C
3.9 Capacitance. When tested as specified in 4.8.4, the capacitance shall not exceed the specified maximum
value (see 3.1).
3.10 Peak current rating. When tested as specified in 4.8.5, the resistors shall have a peak single pulse transient
current rating as specified (see 3.1) without exceeding the specified peak current clamping voltage (see 3.1). Upon
completion, the resistors shall meet the following requirements:
Clamping voltage (see 3.8)
-
Change shall not exceed +20%.
Nominal voltage (see 3.7)
-
Change shall not exceed -10%.
Visual examination
-
There shall be no evidence of mechanical damage
3.11 Pulse life rating. When tested as specified in 4.8.6, the resistors shall have a pulse life rating as specified
(see 3.1). Upon completion of the test, the resistors shall meet the following requirements:
Clamping voltage (see 3.8)
-
Change shall not exceed +20%.
Nominal voltage (see 3.7)
-
Change shall not exceed -10%.
Visual examination
-
There shall be no evidence of mechanical damage
3.12 Energy rating. When tested as specified in 4.8.7, the resistors shall have an energy rating as specified
(see 3.1). Upon completion of the test, the resistors shall meet the following requirements:
Clamping voltage (see 3.8)
-
Change shall not exceed +20%.
Nominal voltage (see 3.7)
-
Change shall not exceed -10%.
Visual examination
-
There shall be no evidence of mechanical damage
3.13 Dielectric withstanding voltage. When tested as specified in 4.8.8, the resistors shall meet the following
requirements:
Leakage current
-
Shall not exceed 1 milliampere at any time during test
Visual examination
-
There shall be no evidence of mechanical damage
3.14 Solderability. When tested as specified in 4.8.9, the resistors shall meet the criteria for wire-lead terminal
evaluation in the test method.
3.15 Resistance to soldering heat. When tested as specified in 4.8.10, the resistors shall meet the following
requirements:
Clamping voltage (see 3.8)
-
Change shall not exceed +20%.
Nominal voltage (see 3.7)
-
Change shall not exceed -10%.
Visual examination
-
There shall be no evidence of mechanical damage
3.16 Resistance to solvents. When tested as specified in 4.8.11, there shall be no evidence of mechanical
damage to the body and the marking shall remain clear and legible.
3.17 Flammability (external flame). When tested as specified in 4.8.12, the time for flaming combustion of resistors
to self-extinguish shall not exceed 7 seconds on any test. The average of all tests, the time to self-extinguish shall
not exceed 5 seconds. The time of persistence of glowing combustion of resistors shall not exceed 30 seconds after
removal of test flame. Resistors shall not drip flaming particles that ignite dry absorbent surgical cotton.
3.18 Terminal strength. When tested as specified in 4.8.13, there shall be no evidence of breaking or loosening of
terminals from the resistor form, chipping of coating, or any other evidence of mechanical damage.