4.6.2.1 Sampling plan.
4.6.2.1.1 Subgroup 1. A sample of parts shall be randomly selected in accordance with table VI. If one or more
defects are found, the lot shall be reworked or screened and defectives removed. After reworking or screening and
removal of defectives, a new sample of parts shall be randomly selected in accordance with table VI. If one or more
defects are found in the second sample, the lot shall be not supplied to this specification.
TABLE V. Group B inspection.
Inspection
Requirement
Test method
Sampling
paragraph
paragraph
plan
Subgroup 1
Dielectric withstanding voltage
Subgroup 2 1/
Resistance to solvents
Subgroup 3 1/
Terminal strength (lead fatigue)
Moisture resistance
Peak current
Energy rating
1/ If the manufacturer can demonstrate that this test has been performed five consecutive
times with zero failures, this test, with the approval of the qualifying activity, can be
deleted. The manufacturer, however, shall perform this test every three years after the
deletion as part of long term design verification. If the design, material, construction, or
processing of the part is changed or, if there are any quality problems, the qualifying
activity may require resumption of the specified testing. Deletion of testing does not
relieve the manufacturer from meeting the test requirement in case of dispute.
4.6.2.1.2 Subgroup 2. A sample of 12 parts shall be randomly selected. If one or more defects are found, the lot
shall be reworked or screened and defectives removed. After reworking or screening and removal of defectives, a
new sample of 12 parts shall be randomly selected. If one or more defects are found in the second sample, the lot
shall be not supplied to this specification.
4.6.2.1.3 Subgroup 3. A sample of parts shall be randomly selected in accordance with table VI. If one or more
defects are found, the lot shall be reworked or screened and defectives removed. After reworking or screening and
removal of defectives, a new sample of parts shall be randomly selected in accordance with table VI. If one or more
defects are found in the second sample, the lot shall be not supplied to this specification.
4.6.2.1.4 Disposition of sample units. Sample units which have been subjected to Group B subgroups II or III shall
not be delivered on the contract or order.