MIL-PRF-83530C
4.8.14 High temperature life (stabilization bake) (see 3.19). Resistors shall be tested in accordance with
method 1032 of MIL-STD-750. The following details and exception shall apply:
Test temperature - Maximum rated temperature (see 3.1).
a.
b.
Duration - 24 hours ± 1 hour.
c.
Examination after test - Resistors shall be visually examined for evidence of mechanical damage.
4.8.15 Thermal shock (see 3.20). Resistors shall be tested in accordance with method 107 of MIL-STD-202. The
following details and exceptions shall apply:
a.
Test condition - A, except that step 3 shall be the applicable maximum rated temperature (see 3.1).
b.
Examination after test - Resistors shall be visually examined for evidence of mechanical damage.
4.8.16 Power burn-in (see 3.21). Resistors shall be tested in accordance with method 1038 of MIL-STD-750. The
following details shall apply:
a.
Test condition - B.
Test temperature - 85°C.
b.
c.
Voltage applied - Maximum rated ac voltage (see 3.1).
d.
Duration - 72 hours +4 hours, -0 hours.
e.
Examination after test - Resistors shall be visually examined for evidence of mechanical damage.
4.8.17 Moisture resistance (see 3.22). Resistors shall be tested in accordance with method 106 of MIL-STD-202.
The following details and exceptions shall apply:
a.
Load and polarization voltages - Not applied.
b.
Measurements after test - Nominal voltage and dielectric withstanding voltage shall be measured as
c.
Examination after test - Resistors shall be visually examined for evidence of mechanical damage.
4.8.18 Vibration (see 3.23). Resistors shall be tested in accordance with method 204 of MIL-STD-202. The
following details and exceptions shall apply:
a.
Mounting - Resistors shall be rigidly fastened to the test platform and the leads secured.
b.
Voltage applied - Resistors shall not be energized.
c.
Test condition - D (20 G; 10 - 2,000 Hz).
Measurements after test - Nominal voltage and clamping voltage shall be measured as specified in 4.8.2 and
d.
4.8.3 respectively.
e.
Examination after test - Resistors shall be visually examined for evidence of mechanical damage.
16
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business