MIL-PRF-39015/1H
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification.
This section does not include documents cited in other sections of this specification or recommended for
additional information or as examples. While every effort has been made to ensure the completeness of
this list, document user are cautioned that they must meet all specified requirements documents cited in
sections 3 and 4 of this specification, whether or not they are listed.
2.2 Government documents.
*
2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and
handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the
issues of these documents are those cited in the solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-PRF-39015 - Resistors, Variable, Wire Wound, (Lead Screw Actuated), Nonestablished
Reliability and Established Reliability, General Specification for.
(Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or
https://assist.daps.dla.mil or from the Standard Document Order Desk, 700 Robbins Avenue, Building 4D,
Philadelphia PA 19111-5094.)
2.3 Order of precedence. In the event of a conflict between the text of this document and the
references cited herein, the text of this document takes precedence. Nothing in this document, however,
supersedes applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 General. The requirements for acquiring the product described herein shall consist of this
document and MIL-PRF-39015.
3.2 Design and construction. Resistors shall be of the design, construction, and physical dimensions
specified on figure 1.
3.3 Power rating. The power rating shall be 3/4 watt, based on full load operation at an ambient
temperature of 85°C.
3.4 Nominal resistance value, maximum resolution, and maximum rated ac or dc working voltage.
Nominal resistance value, maximum resolution, and maximum rated ac or dc working voltages shall be as
specified in table I.
3.5 Actual effective electrical travel. Actual effective electrical travel shall be 17 turns minimum, and 27
turns maximum.
3.6 Operating torque. Operating torque shall be a maximum of 8 ounce-inches.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business