APPENDIX A
A.5.2 Qualifying activity approval. Approval of the solder dip process will be based on one of
the following options:
a. When the original lead finish qualified was hot solder dip lead finish 52 of MIL-STD-1276
(NOTE: The 200 microinch maximum thickness is not applicable). The manufacturer shall
use the same solder dip process for retinning as is used in the original manufacture of the
product.
b. When the lead originally qualified was not hot solder dip lead finish 52 of MIL-STD-1276 as
prescribed in A.5.2a, approval for the process to be used for solder dip shall be based on
the following test procedure:
(1) Thirty samples of any resistance value for each style and lead finish are subjected to
the manufacturing solder dip process. Following the solder dip process, the resistors
are subjected to the dc resistance test (and other group A electricals). No defects are
allowed.
(2) Ten of the 30 samples are then subjected to the solderability test. No defects are allowed.
(3) The remaining 20 samples are subjected to the resistance to solder heat test followed
by the moisture resistance test.
(NOTE: Solder dip of gold plated leads is not allowed.)
A.5.3 Solder dip/retinning options. The manufacturer (or authorized category B or C distributor)
may solder dip/retin as follows:
a. After the 100 percent group A screening tests. Following the solder dip/retinning process,
the electrical measurements required in group A, subgroup 1, 100 percent screening tests
shall be repeated on 100 percent of the lot. (NOTE: The manufacturer may solder dip/retin
prior to the 100 percent electrical measurements of the group A, subgroup 1 tests.) The
percentage defective allowable (PDA) for the electrical measurements, shall be as for the
subgroup 1 tests.
b. As a corrective action, if the lot fails the group A solderability test. The lot may be retinned
no more than two times. The lot after retinning shall be 100 percent screened for group A
electrical requirements (dc resistance) and parts failing (lot not exceeding PDA for group A,
subgroup 1 (see 4.6.3.2.1)) these screens shall not be supplied to this specification, if
electrical failures are detected after the second retinning operation exceeding 1 percent of
the lot, the lot shall not be supplied to this specification..
c. After the group A inspection has been completed. Following the solder dip/retinning
process, the electrical measurements required in group A, subgroup 1, 100 percent
screening test shall be repeated on 100 percent of the lot. The PDA for the electrical
measurements shall be as for the subgroup 1 tests. Following these tests, the
manufacturer shall submit the lot to the group A solderability test as specified in 4.8.6.
38