MIL-PRF-29C
4. VERIFICATION
4.1 Classification of inspection. The inspections requirements specified herein are classified as follows:
Qualification inspection (see 4.4).
a.
b.
Retention of qualification (see 4.5).
Conformance inspection (see 4.6).
c.
4.2 Reliability and quality.
4.2.1 QPL system. The manufacturer shall established and maintain a QPL system. Evidence of such compliance
is a prerequisite for qualification and retention of qualification.
4.3 Inspection conditions.
4.3.1 Inspection conditions. Unless otherwise specified herein, all inspections shall be performed in accordance
4.4 Qualification inspection. Qualification inspection shall be performed at a laboratory acceptable to the
Government (see 6.3) on sample units produced with equipment and procedures normally used in production.
4.4.1 Sample. The number of sample units comprising a sample of resistors to be submitted for qualification
inspection shall be as specified in the appendix A to this specification. (see A.3.1)
4.4.2 Test routine. Sample units will be subjected to the qualification inspection specified in table II, in the order
shown.
TABLE II. Qualification inspection.
Requirement
Method
Number of
Inspection
paragraph
paragraph
defects allowed
Visual and mechanical inspection
Dielectric withstanding voltage
Insulation resistance
DC resistance
Short-time overload
Temperature rise
0
Resistance temperature characteristics
Thermal shock
Salt water immersion cycling
Vibration
Security of ferrules
Mechanical strength
4.4.3 Defectives. Defectives in excess of those allowed in table II shall be cause for refusal to grant qualification.