MIL-PRF-29C
APPENDIX A
PROCEDURE FOR QUALIFIACTION INSPECTION
A.1. SCOPE
A.1.1 Scope. This appendix details the procedures for submission for qualification inspection of resistors covered
by this specification. The procedure for extending qualification of the required sample to other resistors covered by
this specification is also outlined herein. This is a mandatory part of this specification. The information contained
herein is intended for compliance.
A.2. APPLICABLE DOCUMENTS
This section is not applicable to this appendix.
A.3. SUBMISSION
A.3.1 Sample. A sample consisting of three sample units of the highest resistance value for which qualification is
sought shall be submitted. After qualification has been granted, no change shall be made in materials, design, or
construction without prior notification to the qualifying activity.
A.4. EXTENT OF QUALIFICATION
A.4.1 Extent of qualification. Qualification of a resistance value in the style submitted will also qualify all lesser
resistance values in the same style, as well as lesser resistance values in other styles, as specified in table A-I. The
resistor styles to which qualification is extended shall be of the same general construction and materials as the
sample unit submitted.
TABLE A-I. Extent of qualification.
Style submitted
Resistance values
Styles qualified
for inspection
qualified
MFF
MFF,
MFE,
MFD,
MFA,
MFB,
MFC
MFE
MFE,
MFD,
MFA,
MFB,
MFC
MFD
MFD,
MFA,
MFB,
MFC
Up to highest resistance
value submitted
MFA
MFA,
MFB,
MFC
MFB
MFB,
MFC
MFC
MFC