MIL-PRF-23648F
d. Number and direction of applied shocks: The thermistors shall be subjected to a total of ten
shocks in each of two mutually perpendicular planes (one perpendicular and the other parallel to
longitudinal axis of the thermistor).
e. Measurements during shock: Each thermistor shall be monitored to determine electrical
discontinuity by a method which shall at least be sensitive enough to monitor or register
automatically any electrical discontinuity of 0.1 millisecond or greater duration.
f. Measurement after shock: Zero power resistance shall be measured at 25°C as specified in 4.8.2.
g. Inspection after test: Thermistors shall be inspected for evidence of mechanical and electrical
damage.
202. The following details and exceptions shall apply:
a. Test condition letter: B.
b. Inspection after last cycle: There shall be no evidence of mechanical damage.
c. Resistance measurement: Measure zero power resistance not later than 24 hours after the last
cycle as specified in 4.8.2. Within 2 hours, insulation resistance shall be performed in accordance
with 4.8.6.
of MIL-STD-202. The following details shall apply:
a. Marked portion of thermistor shall be brushed.
b. The number of sample units shall be as specified in tables IV and VII, as applicable.
c. Thermistors shall be inspected for mechanical damage and legibility of markings.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the
contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house
contractor personnel, these personnel need to contact the responsible packaging activity to ascertain
packaging requirements. Packaging requirements are maintained by the Inventory Control Point's
packaging activity within the Military Service or Defense Agency, or within the military services system
commands. Packaging data retrieval is available from the managing Military Department's or Defense
Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging
activity.