3.20 Life. When tested as specified in 4.7.15, resistors shall meet the following requirements:
Resistance between end
Change shall not exceed applicable value for total resistance specified in
terminals, with the contact arm in
table I between the initial measurements and each of the succeeding
the position for setting stability:
measurements.
Change shall not exceed 2 percent for characteristic A, and 1 percent for
Setting stability:
characteristic C and characteristic F.
Change shall not exceed the applicable value specified in table I.
Total resistance:
Dielectric withstanding voltage at
As specified in 3.10.
(atmospheric pressure):
Shall not exceed 150 percent of the specified operating torque (see 3.1).
Operating torque:
Visual inspection:
There shall be no evidence of mechanical damage.
3.21 Low temperature operation. When resistors are tested as specified in 4.7.16, resistors shall meet the
following requirements:
Setting stability:
Change shall not exceed 2 percent.
Operating torque:
Shall not exceed 150 percent of the specified operating torque (see 3.1).
Change shall not exceed the applicable value specified in table I.
Total resistance:
Visual inspection:
There shall be no evidence of mechanical damage.
3.22 High temperature exposure. When resistors are tested as specified in 4.7.17, resistors shall meet the
following requirements:
Setting stability:
Change shall not exceed 2 percent.
Total resistance:
Change shall not exceed the applicable value specified in table I.
Operating torque:
Shall not exceed 150 percent of the specified operating torque.
Dielectric withstanding voltage (at
As specified in 3.10.
atmospheric pressure):
Insulation resistance:
Shall not be less than 1,000 megohms.
Visual inspection:
There shall be no evidence of mechanical damage.
3.23 Rotational life. When resistors are tested as specified in 4.7.18, the change in total resistance shall not
exceed the applicable value specified in table I. There shall be no evidence of mechanical damage.
3.24 Terminal strength. When resistors are tested as specified in 4.7.19, there shall be no evidence of mechanical
damage, and resistors shall be electrically continuous.