6.4.5 Vernier (interpolating) rheostat. A vernier rheostat is a rheostat that, in addition to one or more main plates,
has an interpolating plate controlled by a separate knob or handwheel on a shaft concentric to the operating shaft of
the main plates.
6.5 Sub-contracted material and parts. The packaging requirements of referenced documents listed in section 2
do not apply when material and parts are acquired by the contractor for incorporation into the equipment and lose
their separate identity when the equipment is shipped.
6.6 Provisioning. Provisioning Technical documentation (PTD), spare parts, and repair parts should be furnished
as specified in the contract.
6.6.1 When ordering spare parts or repair parts for the equipment covered by this specification, the contract should
state that such spare parts and repair parts should meet the same requirements and quality assurance provisions as
the parts used in the manufacture of the equipment. Packaging for such parts should also be specified.
6.7 Subject term (key word) listing.
Circuit voltage
Interpolating plate
Sliding brush
6.8 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect
to the previous issue due to the extensiveness of the changes.
Custodians:
Preparing activity:
Navy - SH
DLA - CC
DLA - CC
(Project 5905-1607)
Review activities:
Navy - AS