MIL-R-19365E
TABLE V. Qualification inspection.
Inspection |
Requirement paragraph |
Method paragraph |
Number of failure allows |
Group I DC resistance Visual and mechanical examination 1/ |
3.7 3.1, 3.3 to 3.5 incl., 3.19 to 3.23 incl. |
4.7.1 4.7.2 |
0 |
Group II Resistance temperature characteristic Temperature Dielectric withstanding voltage Insulation resistance Power rating Thermal shock Short time overload Moisture resistance Mechanical strength Terminal strength |
3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 |
4.7.3 4.7.4 4.7.5 4.7.6 4.7.7 4.7.8 4.7.9 4.7.10 4.7.11 4.7.12 |
1 |
Group III Life |
3.18 |
4.7.13 |
|
Group IV Visual and mechanical examination |
3.1, 3.3 to 3.5 incl., 3.19 to 3.23 incl. |
4.7.2 |
0 |
1/ Marking will be considered defective only if the marking is illegible.
4.6 Conformance inspection.
4.6.1 Inspection of product for delivery. Inspection of product for delivery shall consist of group A and B
inspection.
4.6.1.1 Inspection lot. An inspection lot, as far as practical, shall include resistors of any style within a given group shown in table V without regard to resistance value or resistance tolerance, produced under essentially uniform conditions and offered for inspection at one time. Resistors that differ in design, construction, materials, and terminal type shall not be included in one lot.
4.6.2 Group A inspection. Group A inspection shall consist of the examinations and test specified in table VI, and shall be made on the same set of sample units, in the order shown.
TABLE VI. Group A inspection.
Test |
Requirement paragraph |
Method Paragraph |
Number of samples |
DC resistance Visual and mechanical examination Overall body dimensions Other physical dimensions Terminals Marking Workmanship |
3.7 3.4 3.4 3.4.3, 3.4.3.1 3.19 3.23 |
4.7.1 4.7.2 |
See 4.6.2.1 |
16