MIL-PRF-27208F
3.16 Moisture resistance. When tested as specified in 4.7.11, resistors shall meet the following requirements:
Change shall not exceed ±(1 percent +0.05 ohms).
Total resistance:
Insulation resistance:
Shall be not less than 100 megohms.
Visual examination:
There shall be no evidence of mechanical damage.
3.17 Shock (specified pulse). When resistors are tested as specified in 4.7.12, the change in total resistance shall
not exceed ±(1 percent +0.05 ohms). The change in setting stability shall not exceed 1 percent plus the specified
maximum resolution (see 3.1), and there shall be no electrical discontinuity or evidence of mechanical damage.
3.18 Vibration, high frequency. When resistors are tested as specified in 4.7.13, there shall be no electrical
discontinuity, and resistors shall meet the following requirements.
Setting stability:
Change shall not exceed 1 percent plus the
maximum specified resolution (see 3.1).
Change shall not exceed ±(1 percent +0.05 ohms).
Total resistance:
Operating voltage:
Shall not exceed 150 percent of the specified
operating torque (see 3.1).
Visual examination:
There shall be no evidence of mechanical damage.
3.19 Salt spray (corrosion). When resistors are tested as specified in 4.7.14, there shall be no appreciable
corrosion.
3.20 Resistance to soldering heat (applicable to terminal type P,W,X, and Y). When resistors are tested as
specified in 4.7.15, the change in total resistance shall not exceed ±(1 percent +0.05 ohms) and there shall be no
evidence of mechanical failure.
3.21 Life. When tested as specified in 4.7.16, resistors shall meet the following requirements:
Resistance between end terminals,
Change shall not exceed 2 percent plus the specified
maximum resolution (see 3.1) between the initial
with the contact arm in the position
measurements and each of the succeeding measurements.
for setting stability:
Setting stability:
Change shall not exceed 2 percent plus the specified
maximum resolution (see 3.1).
Total resistance
Change shall not exceed 2 percent.
Dielectric withstanding voltage at
As specified in 3.11.
atmospheric pressure:
Operating torque
Shall not exceed 150 percent of the specified operating
torque (see 3.1).
Visual examination:
There shall be no evidence of mechanical damage.