MIL-PRF-22684F
4.4.2 Inspection routine. Sample units shall be subjected to the qualification inspection specified in table II, in the
order shown. All sample units except those designated for solderability shall be subjected to the inspection of group I.
Forty sample units shall then be divided equally into four groups for groups II to V inclusive; the remaining 10 units
shall be subjected to group VI.
4.4.3 Defectives. Defectives in excess of those allowed in table II shall be cause for refusal to grant qualification
approval.
4.4.4 Retention of qualification. Every year, the manufacturer shall verify the retention of qualification to the
qualifying activity. In addition, the manufacturer shall immediately notify the qualifying activity whenever the group B
results indicate failure of the qualified product to meet the requirements of the specification. Verification shall be
based on meeting the following requirements:
a. The manufacturer has not modified the design of the item.
b. The specification requirements for the item have not been amended so far as to affect the character of the item.
c. Lot rejection for group A inspection does not exceed the group A sampling plan.
d. The requirements for group B inspection are met.
When group B requirements were not met and the manufacturer has taken corrective action satisfactory to the
Government, group B inspection retesting shall be instituted.
4.4.5 Alternate inspection. For the purpose of retention of qualification and conformance inspection (see 4.4,
4.5 Conformance inspection.
4.5.1 Inspection of product for delivery. Inspection of product for delivery shall consist of group A and group B
inspection. Delivery of shipment shall not be delayed pending completion of group B testing.
4.5.1.1 Inspection lot. An inspection lot, as far as practical, shall consist of all the resistors of the same style,
characteristic, and protective enclosure or coating and manufactured under essentially the same process and
conditions during a manufacturing period of 1 month maximum.
4.5.1.1.1 Production lot. A production lot shall consist of all resistors of the same style, nominal resistance value,
resistance tolerance, and termination type.