A-A-55088C
TABLE I. Fusing characteristics.
Dash
Resistance
Steady state
Blow condition I
Blow condition II
number
(ohms)
Current Dissipation
Current
Dissipation Blow time
Current
Dissipation Blow time
(watts)
(watts)
(T max)
(watts)
(T max)
-01
0.2
2.2 A
1.0
10 A
20
500 ms
25 A
125
50 ms
-02
0.2
2.2 A
1.0
10 A
20
300 ms
25 A
125
30 ms
-03
0.5
1.4 A
1.0
6A
18
10 sec
15 A
112
100 ms
-04
0.5
1.4 A
1.0
6A
18
500 ms
15 A
112
50 ms
-05
0.5
1.4 A
1.0
6A
18
50 ms
15 A
112
10 ms
-06
1.0
1.0 A
1.0
4A
16
10 sec
10 A
100
100 ms
-07
1.0
1.0 A
1.0
4A
16
500 ms
10 A
100
50 ms
-08
1.0
1.0 A
1.0
4A
16
50 ms
10 A
100
10 ms
-09
2.0
700 mA
1.0
3A
18
10 sec
7A
98
50 ms
-10
2.0
700 mA
1.0
3A
18
200 ms
7A
98
50 ms
-11
2.0
700 mA
1.0
3A
18
50 ms
7A
98
10 ms
-12
5.0
450 mA
1.0
2A
20
200 ms
4.5 A
101
50 ms
-13
5.0
400 mA
0.8
1.5 A
10
50 ms
4.0 A
80
10 ms
-14
5.0
350 mA
0.6
1.0 A
5
100 ms
1.4 A
10
20 ms
-15
10
300 mA
0.9
1.2 A
14
200 ms
3.0 A
90
10 ms
-16
10
300 mA
0.9
1.0 A
10
100 ms
1.3 A
17
50 ms
-17
10
200 mA
0.4
600 mA
3.6
100 ms
900 mA
8
50 ms
-18
20
220 mA
1.0
600 mA
7.2
10 sec
900 mA
16
100 ms
-19
20
220 mA
1.0
600 mA
7.2
100 ms
900 mA
16
50 ms
-20
20
150 mA
0.4
350 mA
2.4
500 ms
450 mA
4
50 ms
-21
50
140 mA
1.0
400 mA
8.0
500 ms
600 mA
18
50 ms
-22
50
130 mA
0.8
350 mA
6.1
100 ms
450 mA
10
50 ms
-23
50
80 mA
0.3
200 mA
2.0
200 ms
240 mA
2.9
50 ms
-24
100
100 mA
1.0
250 mA
6.2
10 sec
300 mA
9.0
100 ms
-25
100
80 mA
0.6
200 mA
4.0
200 ms
250 mA
6.2
250 ms
-26
100
60 mA
0.4
140 mA
2.6
10 sec
180 mA
3.2
200 ms
-27
200
70 mA
1.0
200 mA
8.0
10 sec
250 mA
12.5
100 ms
-28
200
60 mA
0.8
150 mA
4.0
100 ms
250 mA
12.5
10 ms
7. NOTES
7.1 PIN. The PIN should be used for Government purposes to buy commercial products to this CID.
See section 2 for PIN format example.
7.2 Environmentally preferable material. Environmentally preferable materials should be used to the
*
maximum extent possible to meet the requirements of this specification. As of the dating of this
document, the U.S. Environmental Protection Agency (EPA) is focusing efforts on reducing 31 priority
chemicals. The list of chemicals and additional information is available on their website at
https://www.epa.gov/osw/hazard/wastemin/priority.htm. Included in the EPA list of 31 priority chemicals
are cadmium, lead, and mercury. Use of these materials should be minimized or eliminated unless
needed to meet the requirements specified herein (see Section 3)."
7.3 Commercial and Government Entity (CAGE) code. For ordering purposes, inventory control, and
submission of these resistors to DSCC under the Military Parts Control Advisory Group (MPCAG)
evaluation program, CAGE code 58536 should be used.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business