MIL-R-26/5D
R100 = 0.1 ohm
1R00 = 1.0 ohm
10R0 = 10.0 ohm
Minimum and maximum resistance values are as specified herein. The standard values for every decade should follow the sequence demonstrated for the "10 to 100" decade in accordance with MIL-PRF-26.
TABLE I. Characteristic.
Symbol |
Maximum continuous operation temperature 1/ |
Minimum insulation resistance at end of moisture resistance |
Resistance temperature characteristic (ppm/0C) |
U 2/ |
2750C |
100 Megohms |
0 ±20 > 20 ohms |
0 ±30 > 10 ohms to <20 ohms |
|||
0 ±50 >1 ohm to <10 ohms |
|||
0 +400, -100 > 0.499 ohm to < 1 ohm |
|||
0 +650, -100 > 0.1 ohm to < 0.499 ohm |
1/ This temperature is also the maximum permissible hot-spot surface temperature.
2/ Inductive wirewound.
1.2.3.1 Replacement or maintenance (applicable to .1 and .5 percent tolerances). It is preferred that resistance values be selected as specified in MIL-PRF-26. However, if it is impracticable to do so, then any value (within specification limits) may be specified and these values shall be considered as conforming to the specification.
1.2.4 Resistance tolerance The resistance tolerance is identified by a single letter in accordance with table II.
TABLE II. Resistance tolerance.
Symbol |
Resistance tolerance percent (±%) |
B D F |
0.1 .05 1.0 |
2. APPLICABLE D0CUMENTS
2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed.