MIL-PRF-83401/9E
TABLE II. Power ratings.
Element power
Network power
Schematic
Characteristic
rating (watts)
rating (watts)
0.54
0.06
C
1.08
0.12
H
C
1.08
0.12
K
1.08
0.12
M
0.54
0.06
V
0.30
0.06
C
0.60
0.12
H
G
0.60
0.12
K
0.60
0.12
M
0.30
0.06
V
0.04
0.54
C
0.07
1.08
H
H
0.07
1.08
K
0.07
1.08
M
V
0.04
0.54
3.4 Power conditioning. The power applied for power conditioning for schematics C, G, and H shall be 1.5 times
rated power.
3.5 Voltage rating. The maximum continuous working voltage for each resistor shall not exceed 50 volts dc or ac
rms.
3.6 Resistance. Minimum and maximum resistance values shall be as follows:
Resistance
Minimum
Maximum
tolerance
resistance
resistance
(megohm)
(ohms)
0.1
100.0
B (±0.1 percent)
0.1
100.0
D (±0.5 percent)
1.0
10.0
F (±1.0 percent)
1.0
10.0
G (±2.0 percent)
1.0
10.0
J (±5.0 percent)
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection shall be in accordance with MIL-PRF-83401.
4.2 H schematic tests. For the tests on H schematic, the dc resistance measurements, resistance temperature
characteristic measurement, and short time overload power application shall be made between each terminal and the
applicable common terminal without compensation for the shunt circuits. The pin to pin dc resistance measurements
shall be used directly to determine the acceptability to section 3 requirements.