MIL-PRF-49465C
TABLE V. Qualification inspection.
Number of
Number of
Requirement
Method
sample units
failures
Inspection
Paragraph
paragraph
1/
allowed
Group I
Visual and mechanical inspection 2/
All samples
80
DC resistance 3/
Group II 4/
Solderability
6
Resistance to solvents
8
Group III 4/
Thermal shock
1
Resistance temperature characteristic
Low temperature storage
20
Short time overload
(10 highest
Dielectric withstanding voltage
10 lowest)
Insulation resistance
Moisture resistance
Terminal strength
Group IV 4/
20
Shock (specified pulse)
(10 highest
Vibration, high frequency
10 lowest)
Group V (unenclosed) 4/ 5/
4
Visual and mechanical inspection
(2 highest
0
3.24.1, and 3.27
as applicable
2 lowest)
Group VI 4/
20
Life
(10 highest
1
10 lowest)
Group VII 4/
20
High temperature exposure
(10 highest
1
10 lowest)
Group VIII 4/
0
Fungus
10
1/ See appendix.
2/ Marking shall be considered defective only if illegible or missing. Marking shall remain legible at the end of all tests.
3/ Tests shall not be performed if a manufacturer presents certified data proving tests have been performed on the
qualification sample.
4/ Items subjected to group II through VIII inclusive, must meet requirements of group I.
5/ Unenclosed sample units shall be subjected to visual and mechanical inspection in accordance with group I only.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business