MIL-PRF-23648/20C
FIGURE 2. Derating curve for high ambient temperatures.
3.6 Resistance.
3.6.1 Resistance at 25°C. Standard values shall be as specified in MIL-PRF-23648 except that the 5
percent decade values shall also be used for resistance tolerance F and G. Minimum and maximum
resistance values shall be in accordance with table I.
TABLE I. Minimum and maximum resistance values
(at 25°C) for each available resistance ratio.
Ratio
Ratio
Ratio
48.7 (C)
19.8 (A)
29.4 (B)
Ohms
Ohms
Ohms
300 min
100 min
15k min
3k max
10k max
500k max
3.6.2 Resistance at temperatures other than 25°C. Factors for determining resistance at
temperatures other than 25°C are determined by multiplying the zero-power resistance at 25°C by the
factors shown in table II for the applicable resistance ratio.
3